--filter, -f FL|-f | FL is either a parameter code when DEVICE is given, or a peripheral device type (pdt) (or other) if --enumerate is given. | help + man |
--inhex FN|-i | FN is a filename containing a log page in ASCII hex or binary if --raw also given. | help |
--in, -i FN|-i | Same as --inhex=FN option. | help + man |
--json JO]|-j[=JO | output in JSON instead of plain text Use --json=? for JSON help | help |
--js-file, -J JFN|-J | JFN is a filename to which JSON output is written (def: stdout); | help + man |
--page, -p PG|-p | PG is either log page acronym, PGN or PGN,SPGN where (S)PGN is a (sub) page number | help + man |
--vendor, -M VP|-M | where VP is a vendor/manufacturer (e.g. "sea" for Seagate) or product (group) acronym (e.g. "lto5" for the 5th generation LTO (tape) consortium). | help + man |
-A, --ALL | fetch and decode all the log pages and subpages supported by the DEVICE. (in the manual page but not in --help) | man |
-a, --all | outputs all the log pages supported by the DEVICE. (in the manual page but not in --help) | man |
-b, --brief | shorten the amount of output for some log pages. (in the manual page but not in --help) | man |
-c, --control PC | accepts 0, 1, 2 or 3 for the PC argument: 0 : current threshold values 1 : current cumulative values 2 : default threshold values 3 : default cumulative values The default value is 1 (i.e. current… (in the manual page but not in --help) | man |
-e, --enumerate | this option is used to output information held in this utility's internal tables about known log pages including their name, acronym and fields. (in the manual page but not in --help) | man |
-E, --exclude | this option excludes vendor specific pages and parameters from the output. (in the manual page but not in --help) | man |
-F, --full | this option is only used in two situations: with the Application client (AC) log page and with the --ALL option. (in the manual page but not in --help) | man |
-h, --help | print out the usage message then exit. (in the manual page but not in --help) | man |
-H, --hex | The default action is to decode known log page numbers (and subpage numbers) into text. (in the manual page but not in --help) | man |
-l, --list | lists the names of the logs sense pages supported by this device. (in the manual page but not in --help) | man |
-m, --maxlen LEN | sets the "allocation length" field in the LOG SENSE cdb. (in the manual page but not in --help) | man |
-n, --name | decode some log pages into 'name=value' entries, one per line. (in the manual page but not in --help) | man |
-x, --no_inq | suppresses the output of information obtained from an initial call to the INQUIRY command for the standard response. (in the manual page but not in --help) | man |
-O, --old | Switch to older style options. (in the manual page but not in --help) | man |
-P, --paramp PP | PP is the parameter pointer value to place in a field of that name in the LOG SENSE cdb. (in the manual page but not in --help) | man |
-q, --pcb | show Parameter Control Byte settings (only relevant when log parameters being output in ASCII). (in the manual page but not in --help) | man |
-D, --pdt DT | DT is the peripheral device type (PDT) that is used when it is not available from the DEVICE. (in the manual page but not in --help) | man |
-Q, --ppc | sets the Parameter Pointer Control (PPC) bit in the LOG SENSE cdb. (in the manual page but not in --help) | man |
-r, --raw | output the response in binary to stdout. (in the manual page but not in --help) | man |
-R, --readonly | open the DEVICE read-only (e.g. in Unix with the O_RDONLY flag). (in the manual page but not in --help) | man |
-S, --select | use a LOG SELECT command. (in the manual page but not in --help) | man |
-s, --sp | sets the Saving Parameters (SP) bit. (in the manual page but not in --help) | man |
-t, --temperature | outputs the temperature. (in the manual page but not in --help) | man |
-T, --transport | outputs the transport ('Protocol specific port') log page. (in the manual page but not in --help) | man |
-u, --undefined | to see fields decoded, the --hex option cannot be used. (in the manual page but not in --help) | man |
-v, --verbose | increase level of verbosity. (in the manual page but not in --help) | man |
-V, --version | print out version string then exit. (in the manual page but not in --help) | man |
-L | lists the names of all logs sense pages and subpages supported by this DEVICE. (in the manual page but not in --help) | man |
-N, --new | Switch to the newer style options. (in the manual page but not in --help) | man |
-paramp PP | PP is the parameter pointer value (in hex) to place in command. (in the manual page but not in --help) | man |
-pcb | show Parameter Control Byte settings (only relevant when log parameters being output in ASCII). (in the manual page but not in --help) | man |
-ppc | sets the Parameter Pointer Control (PPC) bit. (in the manual page but not in --help) | man |
-select | use a LOG SELECT command. (in the manual page but not in --help) | man |
-sp | sets the Saving Parameters (SP) bit. (in the manual page but not in --help) | man |
-? | output usage message then exit. (in the manual page but not in --help) | man |