'\" t .\" Title: nvme-disconnect .\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author] .\" Generator: DocBook XSL Stylesheets vsnapshot .\" Date: 09/18/2026 .\" Manual: NVMe Manual .\" Source: NVMe .\" Language: English .\" .TH "NVME\-DISCONNECT" "1" "09/18/2026" "NVMe" "NVMe Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" nvme-disconnect \- Disconnect one or more Fabrics controller(s)\&. .SH "SYNOPSIS" .sp .nf \fInvme\fR [] \fIdisconnect\fR [\-\-device= | \-d ] [\-\-exclude | \-x] [] .fi .SH "DESCRIPTION" .sp Disconnects and removes one or more existing NVMe over Fabrics controllers\&. If the \-\-device option is specified, the controller with that name will be removed\&. If \-\-nqn is given by itself, every controller connected to the subsystem identified by subnqn will be removed\&. If \-\-nqn is combined with any of the other fabrics options below (the same ones \fInvme connect\fR accepts, such as \-\-transport, \-\-traddr, \-\-trsvcid, \-\-host\-traddr, \-\-host\-iface, \-\-hostnqn or \-\-hostid), only the controller(s) matching all of the specified options are removed \(em useful for disambiguating between multiple controllers connected to the same subsystem\&. \-\-device cannot be combined with \-\-nqn or any of the other fabrics options\&. .sp With \-\-exclude, a matching entry is written to the system\-wide NVMe\-oF exclusion list before the controller (or subsystem) is torn down, so that a cooperating orchestrator sees the exclusion in place before the removal event fires and does not immediately reconnect\&. See nvme\-exclusion\-add(1) and the exclusion list overview for details\&. .SH "OPTIONS" .PP \-d , \-\-device .RS 4 Indicates that the controller with the specified name should be removed\&. Cannot be combined with \-\-nqn or any of the fabrics options below\&. .RE .PP \-x, \-\-exclude .RS 4 Write a matching entry to the \fIuser\fR exclusion list before disconnecting, so orchestrators do not auto\-reconnect the controller\&. The entry is built from the controller\(cqs transport parameters (or, with a bare \-\-nqn, from the subsystem NQN)\&. .RE .SH "FABRICS OPTIONS" .sp The following options are common to NVMe over Fabrics commands such as nvme connect: .PP \-a , \-\-traddr= .RS 4 Specify the network address of the controller\&. For transports using IP addressing (e\&.g\&. rdma, tcp), this should be an IP address\&. .RE .PP \-\-concat .RS 4 Enable secure concatenation (TCP)\&. .RE .PP \-c <#>, \-\-reconnect\-delay=<#> .RS 4 Set the delay in seconds before reconnect is attempted after a connection loss\&. .RE .PP \-C , \-\-kxchap\-ctrl\-secret= .RS 4 Controller authentication secret for bi\-directional authentication\&. If not specified, bi\-directional authentication is not attempted\&. .RE .PP \-S , \-\-kxchap\-secret= .RS 4 Host authentication secret (KX\-HMAC\-CHAP)\&. Must be provided in ASCII format as defined in the NVMe specification\&. .RE .PP \-C , \-\-dhchap\-ctrl\-secret= .RS 4 Controller authentication secret for bi\-directional authentication\&. If not specified, bi\-directional authentication is not attempted\&. (deprecated, see \-\-kxchap\-ctrl\-secret) .RE .PP \-S , \-\-dhchap\-secret= .RS 4 Host authentication secret (DH\-HMAC\-CHAP)\&. Must be provided in ASCII format as defined in the NVMe specification\&. (deprecated, see \-\-kxchap\-secret) .RE .PP \-\-disable\-sqflow .RS 4 Disable submission queue flow control\&. .RE .PP \-G, \-\-data\-digest .RS 4 Enable data digest generation/verification (TCP)\&. .RE .PP \-D, \-\-duplicate\-connect .RS 4 Allow duplicate connections to the same subsystem\&. .RE .PP \-g, \-\-hdr\-digest .RS 4 Enable header digest generation/verification (TCP)\&. .RE .PP \-f , \-\-host\-iface= .RS 4 Specify the network interface to use for the connection\&. .RE .PP \-I , \-\-hostid= .RS 4 Specify the host UUID\&. .RE .PP \-q , \-\-hostnqn= .RS 4 Override the default host NQN\&. .RE .PP \-w , \-\-host\-traddr= .RS 4 Specify the source address on the host side of the connection\&. .RE .PP \-k <#>, \-\-keep\-alive\-tmo=<#> .RS 4 Set the keep\-alive timeout in seconds\&. .RE .PP \-\-keyring= .RS 4 Keyring to use for TLS key lookup\&. .RE .PP \-n , \-\-nqn= .RS 4 Specify the NVMe subsystem NQN to connect to\&. .RE .PP \-i <#>, \-\-nr\-io\-queues=<#> .RS 4 Number of I/O queues to create\&. .RE .PP \-P <#>, \-\-nr\-poll\-queues=<#> .RS 4 Number of polling queues to create\&. .RE .PP \-W <#>, \-\-nr\-write\-queues=<#> .RS 4 Number of write queues to create\&. .RE .PP \-Q <#>, \-\-queue\-size=<#> .RS 4 Queue depth for I/O queues\&. .RE .PP \-l <#>, \-\-ctrl\-loss\-tmo=<#> .RS 4 Maximum time in seconds to retry reconnect attempts after controller loss\&. .RE .PP \-s , \-\-trsvcid= .RS 4 Transport service identifier (e\&.g\&. TCP/rdma port)\&. Default is 4420 for RDMA\&. .RE .PP \-T <#>, \-\-tos=<#> .RS 4 Type of service value for the connection (TCP)\&. .RE .PP \-t , \-\-transport= .RS 4 Specify the transport type\&. Supported values include: .RE .sp + .TS allbox tab(:); lt lt lt lt lt lt lt lt lt lt. T{ .sp Value T}:T{ .sp Description T} T{ .sp rdma T}:T{ .sp RDMA (RoCE, iWARP, InfiniBand) T} T{ .sp tcp T}:T{ .sp TCP/IP T} T{ .sp fc T}:T{ .sp Fibre Channel (\fBexperimental\fR) T} T{ .sp loop T}:T{ .sp Local loopback transport T} .TE .sp 1 .PP \-\-tls .RS 4 Enable TLS encryption (TCP)\&. .RE .PP \-\-tls\-key= .RS 4 TLS key for the connection\&. It is recommended to preload keys into the system keyring instead of passing them via the command line\&. .RE .PP \-\-tls\-key\-identity= .RS 4 Identity associated with the TLS key\&. .RE .SH "GLOBAL OPTIONS" .sp The following options are defined at the top\-level nvme command and are available to this subcommand: .PP \-\-dry\-run .RS 4 Print the command that would be executed, but do not actually execute it\&. .RE .PP \-\-no\-ioctl\-probing .RS 4 Disable probing for 64\-bit IOCTL support\&. .RE .PP \-\-no\-retries .RS 4 Disable retry logic on transient errors\&. .RE .PP \-o , \-\-output\-format= .RS 4 Set the reporting format to \fInormal\fR, \fItabular, \*(Aqjson\fR, or \fIbinary\fR\&. Only one output format may be used at a time\&. .RE .PP \-\-output\-format\-version= .RS 4 Select the output format version\&. Version \fI1\fR uses the original field naming, while version \fI2\fR (default) provides more consistent and script\-friendly field names\&. .RE .PP \-\-timeout= .RS 4 Set the timeout for the command in milliseconds\&. .RE .PP \-v, \-\-verbose .RS 4 Increase the level of detail in the output\&. May be specified multiple times to further increase verbosity\&. .RE .sp These options can also be set as machine\-wide defaults in nvme\-cli\&.conf(5)\&. A command\-line flag always overrides the file\&. .SH "EXAMPLES" .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Disconnect all controllers for a subsystem named nqn\&.2014\-08\&.com\&.example:nvme:nvm\-subsystem\-sn\-d78432: .sp .if n \{\ .RS 4 .\} .nf # nvme disconnect \-\-nqn=nqn\&.2014\-08\&.com\&.example:nvme:nvm\-subsystem\-sn\-d78432 .fi .if n \{\ .RE .\} .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Disconnect the controller nvme4 .sp .if n \{\ .RS 4 .\} .nf # nvme disconnect \-\-device=nvme4 .fi .if n \{\ .RE .\} .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Disconnect only the tcp controller for a subsystem at a given traddr, leaving other controllers of the same subsystem (e\&.g\&. over a different transport address) connected: .sp .if n \{\ .RS 4 .\} .nf # nvme disconnect \-\-nqn=nqn\&.2014\-08\&.com\&.example:nvme:nvm\-subsystem\-sn\-d78432 \e \-\-transport=tcp \-\-traddr=192\&.168\&.1\&.100 .fi .if n \{\ .RE .\} .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Disconnect nvme4 and exclude it so orchestrators do not reconnect it: .sp .if n \{\ .RS 4 .\} .nf # nvme disconnect \-\-device=nvme4 \-\-exclude .fi .if n \{\ .RE .\} .RE .SH "SEE ALSO" .sp nvme\-connect(1) nvme\-exclusion\-add(1) .SH "NVME" .sp Part of the nvme\-user suite