NVME-ID-NS-LIST(1) NVMe Manual NVME-ID-NS-LIST(1)

# [NAME](#NAME)

nvme-id-ns-list - Send NVMe Identify List Namespaces, return result and structure

# [SYNOPSIS](#SYNOPSIS)

```
nvme [<global-options>] id ns-list <device> [--namespace-id=<nsid> | -n <nsid>]


                        [--csi=<command_set_identifier> | -y


                        <command_set_identifier>]


                        [--all | -a]
```

# [DESCRIPTION](#DESCRIPTION)

For the NVMe device given, sends an identify command for namespace list and provides the result and returned structure.

The &lt;device&gt; parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1). If the starting namespace in the list always begins with 0 unless the '--namespace-id' option is given to override.

On success, the namespace array is printed for each index and nsid for a valid nsid.

# [OPTIONS](#OPTIONS)

-n &lt;nsid&gt;, --namespace-id=&lt;nsid&gt;

Retrieve the identify list structure starting with the given nsid.

-y &lt;command\_set\_identifier&gt;, --csi=&lt;command\_set\_identifier&gt;

If this value is given, retrieve the identify list structure associated with the specified I/O command set.

-a, --all

Retrieve the identify list structure for all namespaces in the subsystem, whether attached or inactive.

# [GLOBAL OPTIONS](#GLOBAL_OPTIONS)

The following options are defined at the top-level nvme command and are available to this subcommand:

--dry-run

Print the command that would be executed, but do not actually execute it.

--no-ioctl-probing

Disable probing for 64-bit IOCTL support.

--no-retries

Disable retry logic on transient errors.

-o &lt;fmt&gt;, --output-format=&lt;fmt&gt;

Set the reporting format to *normal*, *tabular, 'json*, or *binary*. Only one output format may be used at a time.

--output-format-version=&lt;version&gt;

Select the output format version. Version *1* uses the original field naming, while version *2* (default) provides more consistent and script-friendly field names.

--timeout=&lt;ms&gt;

Set the timeout for the command in milliseconds.

-v, --verbose

Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in [nvme-cli.conf(5)](/man/os/nvme-cli/nvme-cli.conf.5). A command-line flag always overrides the file.

# [EXAMPLES](#EXAMPLES)

•Print the namespaces present for zoned command set in JSON format

```
# nvme id ns-list /dev/nvme0 -y 2 -a -o json
```

•Print the namespaces present for NVM Command Set in normal format

```
# nvme id ns-list /dev/nvme0
```

# [NVME](#NVME)

Part of the nvme-user suite

09/18/2026 NVMe

---

Document: nvme-id-ns-list(1) from nvme-cli 3.1-r1 (Chainguard OS)
Source: https://github.com/linux-nvme/nvme-cli
