| NVME-WDC-PURGE-MO(1) | NVMe Manual | NVME-WDC-PURGE-MO(1) |
NAME
nvme-wdc-purge-monitor - Send NVMe WDC Purge-Monitor Vendor Unique Command, return result
SYNOPSIS
nvme [<global-options>] wdc purge-monitor <device>
DESCRIPTION
For the NVMe device given, send a Vendor Unique WDC Purge-Monitor command and provide the status of the purge command.
Expected status and description :-
| Status Code | Description |
| 0x00 | Purge State Idle. |
| 0x01 | Purge State Done. |
| 0x02 | Purge State Busy. |
| 0x03 | Purge State Error : Purge operation resulted in error, power cycle required. |
| 0x04 | Purge State Error : Purge operation interrupted by power cycle or reset. |
The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
This will only work on WDC devices supporting this feature. Results for any other device are undefined.
On success it returns 0, error code otherwise.
OPTIONS
No options yet.
GLOBAL OPTIONS
The following options are defined at the top-level nvme command and are available to this subcommand:
--dry-run
--no-ioctl-probing
--no-retries
-o <fmt>, --output-format=<fmt>
--output-format-version=<version>
--timeout=<ms>
-v, --verbose
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.
EXAMPLES
# nvme wdc purge-monitor /dev/nvme0
NVME
Part of the nvme-user suite.
| 09/18/2026 | NVMe |