DS1821 - Programmable Digital Thermostat and Thermometer

DS1821(3) One-Wire File System DS1821(3)

DS1821 - Programmable Digital Thermostat and Thermometer

Thermostat.

thermostat [/[ temperature | temphigh | templow | temphighflag | templowflag | thermostatmode | polarity | 1shot ]]

none

read-only, floating point
9-bit resolution temperature. Units are selected from the invoking command line. See owfs(1) or owhttpd(1) for choices. Default is Celsius. Conversion takes 1 second.

read-write. floating point
Temperature limits for alarms. Units are selected from the invoking command line. See owfs(1) or owhttpd(1) for choices. Default is Celsius.
Note that alarms are not implemented.

read-write. yes-no
temphighflag goes to 1 when temperature exceeds temphigh and stays at 1 until it is reset by writing it to zero. This state persists across power cycles and operates in both 1-wire and thermostat modes. templowflag behaves in the same way, monitoring the temperature with respect to templow.

read-write. yes-no
When this bit is set to 1 the chip will enter thermostat mode on the next power-up. See the datasheet for further information on thermostat mode. NOTE: Once the DS1821 has entered thermostat mode it cannot be taken out back to 1-wire mode using a 1-wire interface. Special electrical incantations on the power and data lines must be performed that are not possible with a normal 1-wire bus master. A special circuit is required - see the datasheet for complete details.

read-write. yes-no
Controls the output sense of the thermostat output (DQ) while in thermostat mode. If polarity is 0 the output is active low. If it is 1, active high.

read-write. yes-no
If this bit is 1, a START CONVERT command will begin a conversion and the chip will enter a low power state when the conversion is complete. If the bit is 0 then START CONVERT will begin a conversion and start another one as soon as it is done. STOP CONVERSION must be performed to get the conversion cycle to stop. This interface automatically issues a STOP CONVERSION command when going out of continuous mode.

See the file man3/temperature_threshold.3so.

read-only, ascii
Chip type: DS1821

See the file man3/description.3so.

The DS1821 (3) is a unique 1-wire device. It is unaddressable, and therefore there can be only one on a given bus. It is meant to be programmed once using 1-wire and then permanently installed in a thermostat circuit. Once in thermostat mode, it is no longer programmable from a 1-wire interface. It is possible to recover it into 1-wire mode but only with a special circuit.

Unlike all other 1-wire chips, the ,B DS1821 (3) has no unique address. It is addressed as thermostat and will not announce itself in device discovery (directory listing).

http://pdfserv.maxim-ic.com/en/ds/DS1821.pdf

See the file man3/seealso.3so.

http://www.owfs.org