OS Manuals

IBLSS(3)

IBLSS - iButtonLink SmartSlave

IBLSS(3) One-Wire File System IBLSS(3)

IBLSS - iButtonLink SmartSlave

FE [.]XXXXXXXX2X00[XX][/[ TH/humidity | TH/latesthumidity | TH/temperature | TH/latesttemp | TH/led | firmware | subtype |

See the file man3/standard_mini.3so.

]]

FE

read-only, floating point
Humidity read by the chip at high resolution (~13 bits). Unit is % relative humidity. Negative values indicate a condensing condition. Conversion takes about one second.

read-only, floating point
Latest measured humidity. Reading this node will never trigger a combined humidity/temperature conversion. Intended for use after a previous read of the TH/temperature node or in conjunction with /simultaneous/iblss.

read-only, floating point
Temperature read by the chip at high resolution (~13 bits). Units are selected from the invoking command line. See owfs(1) or owhttpd(1) for choices. Default is Celsius. Conversion takes about one second.

read-only, floating point
Latest measured temperature. Reading this node will never trigger a combined humidity/temperature conversion. Intended for use after a previous read of the TH/humidity node or in conjunction with /simultaneous/iblss.

write-only, yes-no
Switches the indicator LED on/off.

read-only, ascii
Firmware version of the Smart Slave displayed as major.major number. Firmware versions of the SS-WALL-TH before 1.4 had known issues with humidity reporting.

read-only, ascii
Subtype of the Smart Slave. Currently only possible value is "TH" signifying an SS-WALL-TH drywall temperature/humidity sensor.

See the file man3/standard.3so.

None.

See the file man3/description.3so.

See the file man3/addressing.3so.

https://www.ibuttonlink.com/products/ss-wall-th

See the file man3/seealso.3so.

http://www.owfs.org

Paul Alfille <paul.alfille@gmail.com> Jan Kandziora <jjj@gmx.de>

2003 OWFS Manpage

owfs 3.2.4-r8 · os · ingested 2026-09-30