Real time clock.
24 [.]XXXXXXXXXXXX[XX][/[ date | flags | running | udate |

See the file man3/standard_mini.3so.

]]

Clock with interrupts
27 [.]XXXXXXXXXXXX[XX][/[ date | enable | interval | itime | running | udate |

See the file man3/standard_mini.3so.

]]

24
DS2415 DS1904
27
DS2417

read-write, ascii
26 character date representation of the counter value. Increments once per second while running
Setting date to a null string will put the current system time.
Accepted date formats are:
Sat[urday] March 12 12:23:59 2001
Apr[il] 4 9:34:56 2002
3/23/04 23:34:57
current locale setting (your system's format)

read-write, yes-no
State of the timer interrupt. 0=off 1=running.

read-write, unsigned integer
Interval between timer interrupts. Values: 0-7. See table under DESCRIPTION for interpretation. itime will reflect the interval chosen.

read-write, unsigned integer
Interval between timer interrupts. Value in seconds. See table under DESCRIPTION for interpretation and acceptable values. interval will reflect the itime chosen.

read-write, unsigned integer
General use data. 4 bits (0-15 accepted values).

read-write, yes-no
State of the clock. 0=off 1=running.

read-write, unsigned integer
Time represented as a number. udate increments once per second, while running is on.
Usually set to unix time standard: number of seconds since Jan 1, 1970. The date field will be the unix representation of udate and setting either will change the other.

See the file man3/standard.3so.

None implemented.

See the file man3/description.3so.

The DS2415 (3) and DS1904 (3) are simple clocks that can be read on the 1-wire bus. They can also be used the time an event, for remote confirmation.

The DS2417 has the same clock function, but also includes a programmable interval interrupt. Values Allowed are:
0 1sec
1 4sec
2 32s = .5m
3 6 = 1m
4 2048s = .5h
5 4096s = 1h
6 65536s = 18h
7 131072s = 36h

See the file man3/addressing.3so.