'\" '\" Copyright (c) 2003-2004 Paul H Alfille, MD '\" (paul.alfille@gmail.com) '\" '\" Device manual page for the OWFS -- 1-wire filesystem package '\" Based on Dallas Semiconductor, Inc's datasheets, and trial and error. '\" '\" Free for all use. No warranty. None. Use at your own risk. '\" .TH mDI001 3 2003 "OWFS Manpage" "One-Wire File System" .SH NAME .B mDI001 \- Digital Input Module .SH SYNOPSIS .SS Monitor 4 digital lines .PP .B A5 [.]XXXXXXXXXXXX[XX][/[ .B switch_closed.[0-3|ALL|BYTE] | .B loop_open.[0-3|ALL|BYTE] | .B loop_shorted.[0-3|ALL|BYTE] | .so man3/standard_mini.3so ]] .SH FAMILY CODE .PP .I A5 .SH SPECIAL PROPERTIES .SS switch_closed.[0-3|ALL|BYTE] .I read-only, yes-no .br Is the relay closed? (1=yes, 0=no). .P Note that .I OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4. .SS loop_shorted.[0-3|ALL|BYTE] .I read-only, yes-no .br Is the loop shorted? (1=yes, 0=no). Failsafe mode. .P Note that .I OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4. .SS loop_open.[0-3|ALL|BYTE] .I read-only, yes-no .br Is the loop open? (1=yes, 0=no). Failsafe mode. .P Note that .I OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4. .SH STANDARD PROPERTIES .so man3/standard.3so .SH ALARMS None. .SH DESCRIPTION .so man3/description.3so .SS mDI001 The .B mDI001 (3) is used to monitor digital lines for simple switching. .SH ADDRESSING .so man3/addressing.3so .SH WEBSITE .br http://www.cmciel.com/products-solutions/individual-products/4-channel-fail-safe-digital-module-mdi001/ .so man3/seealso.3so .SH AVAILABILITY http://www.owfs.org .SH AUTHOR Paul Alfille (paul.alfille@gmail.com)