TEMPERATURE ERRATA
There are a group of obscure internal properties exposed to protect against an hardware defect in certain batches of the B7 die of some DS18x20 chips. See http://www.1wire.org/en-us/pg_18.html or request AN247.pdf from Dallas directly.
errata/die
read-only,ascii
Two character manufacturing die lot. "B6" "B7" or
"C2"
errata/trim
read-write,unsigned integer
32 bit trim value in the EEPROM of the chip. When written, it does not seem to
read back. Used for a production problem in the B7 die.
Read allowed for all chips. Only the B7 chips can be written.
errata/trimblanket
read-write,yes-no
Writing non-zero (=1) puts a default trim value in the chip. Only applied to
the B7 die. Reading will be true (non-zero) if trim value is the
blanket value. Again, only B7 chips will register true, and since the
written trim values cannot be read, this value may have little utility.
errata/trimvalid
read-only,yes-no
Is the trim value in the valid range? Non-zero if true, which includes
all non-B7 chips.