| SD_BUS_DEFAULT(3) | sd_bus_default | SD_BUS_DEFAULT(3) |
.SH "NAME" sd_bus_default, sd_bus_default_user,
sd_bus_default_system, sd_bus_open, sd_bus_open_with_description,
sd_bus_open_user, sd_bus_open_user_with_description,
sd_bus_open_user_machine, sd_bus_open_system,
sd_bus_open_system_with_description, sd_bus_open_system_remote,
sd_bus_open_system_machine - Acquire a connection to a system or user
bus
.SH "SYNOPSIS"
#include <systemd/sd-bus.h>
.HP 456u int sd_bus_default(sd_bus **bus);
.HP 576u int
sd_bus_default_user(sd_bus **bus);
.HP 624u int
sd_bus_default_system(sd_bus **bus);
.HP 384u int sd_bus_open(sd_bus **bus);
.HP 792u int
sd_bus_open_with_description(sd_bus **bus,
const char *description);
.HP 504u int sd_bus_open_user(sd_bus **bus);
.HP 912u int
sd_bus_open_user_with_description(sd_bus **bus,
const char *description);
.HP 696u int sd_bus_open_user_machine(sd_bus **bus,
const char *machine);
.HP 552u int
sd_bus_open_system(sd_bus **bus);
.HP 960u int
sd_bus_open_system_with_description(sd_bus **bus,
const char *description);
.HP 720u int sd_bus_open_system_remote(sd_bus **bus,
const char *host);
.HP 744u int sd_bus_open_system_machine(sd_bus **bus,
const char *machine);
.SH "DESCRIPTION"
.PP sd_bus_default() acquires a bus connection object to the user bus
when invoked from within a user slice (any session under user-*.slice, e.g.:
user@1000.service), or to the system bus otherwise. The connection object is
associated with the calling thread. Each time the function is invoked from
the same thread, the same object is returned, but its reference count is
increased by one, as long as at least one reference is kept. When the last
reference to the connection is dropped (using the sd_bus_unref(3)
call), the connection is terminated. Note that the connection is not
automatically terminated when the associated thread ends. It is important to
drop the last reference to the bus connection explicitly before the thread
ends, as otherwise, the connection will leak. Also, queued but unread or
unwritten messages keep the bus referenced, see below.
.PP sd_bus_default_user() returns a user bus connection object
associated with the calling thread. sd_bus_default_system() is
similar, but connects to the system bus. Note that sd_bus_default()
is identical to these two calls, depending on the execution context.
.PP sd_bus_open() creates a new, independent bus connection to the
user bus when invoked in user context, or the system bus otherwise.
sd_bus_open_user() is similar, but connects only to the user bus.
sd_bus_open_system() does the same, but connects to the system bus.
In contrast to sd_bus_default(), sd_bus_default_user(), and
sd_bus_default_system(), these calls return new, independent
connection objects that are not associated with the invoking thread and are
not shared between multiple invocations. It is recommended to share
connections per thread to efficiently make use the available resources.
Thus, it is recommended to use sd_bus_default(),
sd_bus_default_user() and sd_bus_default_system() to connect
to the user or system buses.
.PP sd_bus_open_with_description(),
sd_bus_open_user_with_description(), and
sd_bus_open_system_with_description() are similar to
sd_bus_open(), sd_bus_open_user(), and
sd_bus_open_system(), but allow a description string to be set, see
sd_bus_set_description(3). description may be NULL, in
which case this function is equivalent to sd_bus_open(). This
description string is used in log messages about the bus object, and
including a "name" for the bus makes them easier to understand.
Some messages are emitted during bus initialization, hence using this
function is preferable to setting the description later with
sd_bus_open_with_description(). The argument is copied internally and
will not be referenced after the function returns.
.PP If the $DBUS_SESSION_BUS_ADDRESS environment variable is set (cf.
environ(7)), it will be used as the address of the user bus. This
variable can contain multiple addresses separated by ;. If this variable is
not set, a suitable default for the default user D-Bus instance will be
used.
.PP If the $DBUS_SYSTEM_BUS_ADDRESS environment variable is set, it
will be used as the address of the system bus. This variable uses the same
syntax as $DBUS_SESSION_BUS_ADDRESS. If this variable is not set, a
suitable default for the default system D-Bus instance will be used.
.PP sd_bus_open_system_remote() connects to the system bus on the
specified host using ssh(1). host consists of an optional user
name followed by the @ symbol, and the hostname, optionally followed by a :
and a port, optionally followed by a / and a machine name. If the machine
name is given, a connection is created to the system bus in the specified
container on the remote machine, and otherwise a connection to the system
bus on the specified host is created.
.PP Note that entering a container is a privileged operation, and will likely
only work for the root user on the remote machine.
.PP sd_bus_open_system_machine() connects to the system bus in the
specified machine, where machine is the name of a local
container, possibly prefixed by a user name and a separating @. If the
container name is specified as the special string .host the connection is
made to the local system. This is useful to connect to the local system bus
as specific user, e.g. foobar@.host to connect to the local system bus as
local user foobar. If the @ syntax is used either the left-hand side or the
right-hand side may be omitted (but not both) in which case the local user
name or .host is implied. If the @ syntax is not used the connection is
always made as root user. See sd_bus_set_address(3) for a description
of the address syntax, and machinectl(1) for more information about
the "machine" concept. Note that connections into local containers
are only available to privileged processes at this time.
.PP sd_bus_open_user_machine() is similar to
sd_bus_open_system_machine(), but connects to the user bus of the
root user, or if the @ syntax is used, of the specified user.
.PP These calls allocate a bus connection object and initiate the connection
to a well-known bus of some form. An alternative to using these high-level
calls is to create an unconnected bus object with sd_bus_new(3) and
to connect it with sd_bus_start(3).
.SH "REFERENCE OWNERSHIP"
.PP The functions sd_bus_open(), sd_bus_open_user(),
sd_bus_open_user_machine(), sd_bus_open_system(),
sd_bus_open_system_remote(), and sd_bus_open_system_machine()
return a new connection object and the caller owns the sole reference. When
not needed anymore, this reference should be destroyed with
sd_bus_unref(3).
.PP The functions sd_bus_default(), sd_bus_default_user() and
sd_bus_default_system() do not necessarily create a new object, but
increase the connection reference of an existing connection object by one.
Use sd_bus_unref(3) to drop the reference.
.PP Queued but unwritten/unread messages keep a reference to their bus
connection object. For this reason, even if an application dropped all
references to a bus connection, it might not get destroyed right away. Until
all incoming queued messages are read, and until all outgoing unwritten
messages are written, the bus object will stay alive. sd_bus_flush()
may be used to write all outgoing queued messages so they drop their
references. To flush the unread incoming messages, use
sd_bus_close(), which will also close the bus connection. When using
the default bus logic, it is a good idea to first invoke
sd_bus_flush() followed by sd_bus_close() when a thread or
process terminates, and thus its bus connection object should be freed.
.PP Normally, slot objects (as created by sd_bus_add_match(3) and
similar calls) keep a reference to their bus connection object, too. Thus,
as long as a bus slot object remains referenced its bus object will remain
allocated too. Optionally, bus slot objects may be placed in
"floating" mode. When in floating mode the life cycle of the bus
slot object is bound to the bus object, i.e. when the bus object is freed
the bus slot object is automatically unreferenced too. The floating state of
a slot object may be controlled explicitly with
sd_bus_slot_set_floating(3), though usually floating bus slot objects
are created by passing NULL as the slot parameter of
sd_bus_add_match() and related calls, thus indicating that the caller
is not directly interested in referencing and managing the bus slot
object.
.PP The life cycle of the default bus connection should be the responsibility
of the code that creates/owns the thread the default bus connection object
is associated with. Library code should neither call sd_bus_flush()
nor sd_bus_close() on default bus objects unless it does so in its
own private, self-allocated thread. Library code should not use the default
bus object in other threads unless it is clear that the program using it
will life cycle the bus connection object and flush and close it before
exiting from the thread. In libraries where it is not clear that the calling
program will life cycle the bus connection object, it is hence recommended
to use sd_bus_open_system() instead of sd_bus_default_system()
and related calls.
.SH "RETURN VALUE"
.PP On success, these calls return 0 or a positive integer. On failure, these
calls return a negative errno-style error code.
.SS "Errors"
.PP Returned errors may indicate the following problems:
.PP -EINVAL
The specified parameters are invalid.
.RE
.PP -ENOMEDIUM
The requested bus type is not available because of invalid environment (for
example the user session bus is not available because
$XDG_RUNTIME_DIR is not set).
.RE
.PP -ENOMEM
Memory allocation failed.
.RE
.PP -ESOCKTNOSUPPORT
The protocol version required to connect to the selected bus is not
supported.
.RE
.PP In addition, other connection-related errors may be returned. See
sd_bus_send(3).
.SH "NOTES"
.PP Functions described here are available as a shared library, which can be
compiled against and linked to with the
libsystemd pkg-config(1) file.
.PP All functions listed here are thread-agnostic and only a single thread
may operate on a given object at any given time. Different threads may
access the same object at different times. Multiple independent objects may
be used from different threads in parallel.
.PP The code described here uses getenv(3), which is declared to be
not multi-thread-safe. This means that the code calling the functions
described here must not call setenv(3) from a parallel thread. It is
recommended to only do calls to setenv() from an early phase of the
program when no other threads have been started.
.SH "HISTORY"
.PP sd_bus_default(), sd_bus_default_user(),
sd_bus_default_system(), sd_bus_open(),
sd_bus_open_user(), sd_bus_open_system(),
sd_bus_open_system_remote(), and sd_bus_open_system_machine()
were added in version 221.
.PP sd_bus_open_with_description(),
sd_bus_open_user_with_description(), and
sd_bus_open_system_with_description() were added in version 239.
.PP sd_bus_open_user_machine() was added in version 248.
.SH "SEE ALSO"
.PP systemd(1), sd-bus(3), sd_bus_new(3),
sd_bus_ref(3), sd_bus_unref(3), sd_bus_close(3),
ssh(1), systemd-machined.service(8), machinectl(1)
| systemd 262.2 |