| SD_BUS_MESSAGE_READ(3) | sd_bus_message_read | SD_BUS_MESSAGE_READ(3) |
.SH "NAME" sd_bus_message_read, sd_bus_message_readv,
sd_bus_message_peek_type - Read a sequence of values from a message
.SH "SYNOPSIS"
#include <systemd/sd-bus.h>
.HP 576u int sd_bus_message_read(sd_bus_message *m,
const char *types, ...);
.HP 600u int sd_bus_message_readv(sd_bus_message *m,
const char *types,
va_list ap);
.HP 696u int
sd_bus_message_peek_type(sd_bus_message *m,
char *type,
const char **contents);
.SH "DESCRIPTION"
.PP sd_bus_message_read() reads a sequence of fields from the D-Bus
message object m and advances the read position in the message. The
type string types describes the types of items expected in the
message and the field arguments that follow. The type string may be
NULL or empty, in which case nothing is read.
.PP The type string is composed of the elements described in
sd_bus_message_append(3), i.e. basic and container types. It must
contain zero or more single "complete types". The type string is
NUL-terminated.
.PP For each type specified in the type string, one or more arguments need to
be specified after the types parameter, in the same order. The
arguments must be pointers to appropriate types (a pointer to int8_t
for a y in the type string, a pointer to int32_t for an i, a pointer
to const char* for an s, ...) which are set based on the values in
the message. As an exception, in case of array and variant types, the first
argument is an "input" argument that further specifies how the
message should be read. See the table below for a complete list of allowed
arguments and their types. Note that, if the basic type is a pointer (e.g.,
const char * in the case of a string), the argument is a pointer to a
pointer, and also the pointer value that is written is only borrowed and the
contents must be copied if they are to be used after the end of the
message's lifetime. If the type is h (UNIX file descriptor), the descriptor
is not duplicated by this call and the returned descriptor remains in
possession of the message object, and needs to be duplicated by the caller
in order to keep an open reference to it after the message object is
freed.
.PP Each argument may also be NULL, in which case the value is read
and ignored.
.sp
Table 1. Item type specifiers
| Specifier | Constant | Description | Type of the first argument | Types of the subsequent arguments, if any |
| y | SD_BUS_TYPE_BYTE | 8-bit unsigned integer | uint8_t * | |
| b | SD_BUS_TYPE_BOOLEAN | boolean | int * (NB: not bool *) | |
| n | SD_BUS_TYPE_INT16 | 16-bit signed integer | int16_t * | |
| q | SD_BUS_TYPE_UINT16 | 16-bit unsigned integer | uint16_t * | |
| i | SD_BUS_TYPE_INT32 | 32-bit signed integer | int32_t * | |
| u | SD_BUS_TYPE_UINT32 | 32-bit unsigned integer | uint32_t * | |
| x | SD_BUS_TYPE_INT64 | 64-bit signed integer | int64_t * | |
| t | SD_BUS_TYPE_UINT64 | 64-bit unsigned integer | uint64_t * | |
| d | SD_BUS_TYPE_DOUBLE | IEEE 754 double precision floating-point | double * | |
| s | SD_BUS_TYPE_STRING | UTF-8 string | const char ** | |
| o | SD_BUS_TYPE_OBJECT_PATH | D-Bus object path string | const char ** | |
| g | SD_BUS_TYPE_SIGNATURE | D-Bus signature string | const char ** | |
| h | SD_BUS_TYPE_UNIX_FD | UNIX file descriptor | int * | |
| a | SD_BUS_TYPE_ARRAY | array | int, which specifies the expected length n of the array | n sets of arguments appropriate for the array element type |
| v | SD_BUS_TYPE_VARIANT | variant | signature string | arguments appropriate for the types specified by the signature |
| ( | SD_BUS_TYPE_STRUCT_BEGIN | array start | arguments appropriate for the structure elements | |
| ) | SD_BUS_TYPE_STRUCT_END | array end | ||
| { | SD_BUS_TYPE_DICT_ENTRY_BEGIN | dictionary entry start | arguments appropriate for the first type in the pair | arguments appropriate for the second type in the pair |
| } | SD_BUS_TYPE_DICT_ENTRY_END | dictionary entry end | ||
.PP If objects of the specified types are not present at the current position
in the message, an error is returned.
.PP The sd_bus_message_readv() is equivalent to the
sd_bus_message_read(), except that it is called with a va_list
instead of a variable number of arguments. This function does not call the
va_end() macro. Because it invokes the va_arg() macro, the
value of ap is undefined after the call.
.PP sd_bus_message_peek_type() determines the type of the next element
in m to be read by sd_bus_message_read() or similar functions.
On success, the type is stored in type, if it is not NULL. If
the type is a container type, the type of its elements is stored in
contents, if it is not NULL. If this function successfully
determines the type of the next element in m, it returns a positive
integer. If there are no more elements to be read, it returns zero.
.SH "RETURN VALUE"
.PP On success, these functions return a non-negative integer. On failure,
they return a negative errno-style error code.
.SS "Errors"
.PP Returned errors may indicate the following problems:
.PP -EINVAL
Specified type string is invalid or the message parameter is NULL.
.RE
.PP -ENXIO
The message does not contain the specified type at current position.
.RE
.PP -EBADMSG
The message cannot be parsed.
.RE
.PP -EBUSY
When reading from a container, this error will be returned if unread elements
are left in the container.
Added in version 251.
.RE
.SH "NOTES"
.PP Functions described here are available as a shared library, which can be
compiled against and linked to with the
libsystemd pkg-config(1) file.
.PP All functions listed here are thread-agnostic and only a single thread
may operate on a given object at any given time. Different threads may
access the same object at different times. Multiple independent objects may
be used from different threads in parallel.
.PP The code described here uses getenv(3), which is declared to be
not multi-thread-safe. This means that the code calling the functions
described here must not call setenv(3) from a parallel thread. It is
recommended to only do calls to setenv() from an early phase of the
program when no other threads have been started.
.SH "EXAMPLES"
.PP Read a single basic type (a 64-bit integer):
sd_bus_message *m; int64_t x; sd_bus_message_read(m, "x", &x);
.PP Read a boolean value:
sd_bus_message *m; int x; /* Do not use C99 "bool" type here, it is typically smaller
in memory and would cause memory corruption */ sd_bus_message_read(m, "b", &x);
.PP Read all types of integers:
uint8_t y; int16_t n; uint16_t q; int32_t i; uint32_t u; int64_t x; uint64_t t; double d; sd_bus_message_read(m, "ynqiuxtd", &y, &n, &q, &i, &u, &x, &t, &d);
.PP Read a structure composed of a string and a D-Bus path:
const char *s, *p; sd_bus_message_read(m, "(so)", &s, &p);
.PP Read a variant, with the real type "gt" (signature, unsigned
integer):
const char *s; uint64_t *v; sd_bus_message_read(m, "v", "gt", &s, &v);
.PP Read a dictionary containing three pairs of type
{integer=>string}:
int i, j, k;
const char *s, *t, *u;
sd_bus_message_read(m, "a{is}", 3, &i, &s, &j, &t, &k, &u);
.PP Read a single file descriptor, and duplicate it in order to keep it open
after the message is freed.
sd_bus_message *m; int fd, fd_copy; sd_bus_message_read(m, "h", &fd); fd_copy = fcntl(fd, FD_DUPFD_CLOEXEC, 3);
.SH "HISTORY"
.PP sd_bus_message_read() and sd_bus_message_readv() were added
in version 240.
.PP sd_bus_message_peek_type() was added in version 246.
.SH "SEE ALSO"
.PP systemd(1), sd-bus(3), sd_bus_message_read_basic(3),
sd_bus_message_skip(3), sd_bus_message_append(3),
sd_bus_message_enter_container(3)
| systemd 262.2 |