Usage: sg_readcap [--10] [--16] [--brief] [--help] [--hex] [--inhex-FN]
[--json[=JO]] [--js-file=JFN] [--lba=LBA] [--long] [--pmi]
[--raw] [--readonly] [--verbose] [--version] [--zbc]
DEVICE
where:
--10 use READ CAPACITY (10) cdb (this is the default)
--16 use READ CAPACITY (16) cdb (same as --long)
--brief|-b brief, two hex numbers: number of blocks and block size
--help|-h print this usage message and exit
--hex|-H output response in hexadecimal to stdout
--inhex=FN|-i FN contents of file FN treated as hex and used
instead of DEVICE which is ignored
--json[=JO]|-j[=JO] output in JSON instead of plain text
Use --json=? for JSON help
--js-file=JFN|-J JFN JFN is a filename to which JSON output is
written (def: stdout); truncates then writes
--lba=LBA|-L LBA yields the last block prior to (head movement) delay
after LBA [in decimal (def: 0) valid with '--pmi']
--long|-l use READ CAPACITY (16) cdb (def: use 10 byte cdb)
--old|-O use old interface (use as first option)
--pmi|-p partial medium indicator (without this option shows
total disk capacity) [made obsolete in sbc3r26]
--raw|-r output response in binary to stdout
--readonly|-R open DEVICE read-only (def: RCAP(16) read-write)
--verbose|-v increase verbosity
--version|-V print version string and exit
--zbc|-z show rc_basis ZBC field (implies --16)
Perform a SCSI READ CAPACITY (10 or 16) command
Options (21)
| Option | Description | Source |
|---|
--10 | Use the 10 byte cdb variant of the READ CAPACITY command. | help + man |
--16 | Use the 16 byte cdb variant of the READ CAPACITY command. | help + man |
--inhex, -i FN|-i | contents of file FN treated as hex and used instead of DEVICE which is ignored | help + man |
--json JO]|-j[=JO | output in JSON instead of plain text Use --json=? for JSON help | help |
--js-file, -J JFN|-J | JFN is a filename to which JSON output is written (def: stdout); | help + man |
--lba, -L LBA|-L | yields the last block prior to (head movement) delay after LBA [in decimal (def: 0) valid with '--pmi'] | help + man |
-h, --help | print out the usage message then exit. (in the manual page but not in --help) | man |
-H, --hex | output the response to the READ CAPACITY command (either the 10 or 16 byte cdb variant) in ASCII hexadecimal on stdout. (in the manual page but not in --help) | man |
-l, --long | Use the 16 byte cdb variant of the READ CAPACITY command. (in the manual page but not in --help) | man |
-O, --old | Switch to older style options. (in the manual page but not in --help) | man |
-p, --pmi | partial medium indicator: for finding the next block address prior to some delay (e.g. head movement). (in the manual page but not in --help) | man |
-r, --raw | output response in binary to stdout. (in the manual page but not in --help) | man |
-R, --readonly | open the DEVICE read-only (e.g. in Unix with the O_RDONLY flag). (in the manual page but not in --help) | man |
-v, --verbose | increase level of verbosity. (in the manual page but not in --help) | man |
-V, --version | outputs version string then exits. (in the manual page but not in --help) | man |
-z, --zbc | additionally prints out the extra ZBC field (RC_BASIS) in the READ CAPACITY response. (in the manual page but not in --help) | man |
-16 | Use the 16 byte cdb variant of the READ CAPACITY command. (in the manual page but not in --help) | man |
-b | utility outputs two hex numbers (prefixed with '0x' and space separated) to stdout. (in the manual page but not in --help) | man |
-lba LBA | used in conjunction with -pmi option. (in the manual page but not in --help) | man |
-N, --new | Switch to the newer style options. (in the manual page but not in --help) | man |
-pmi | partial medium indicator: for finding the next block address prior to some delay (e.g. head movement). (in the manual page but not in --help) | man |
Exit status (1) from the manual page