| DS2438(3) | One-Wire File System | DS2438(3) |
NAME
DS2438 - Smart Battery Monitor
SYNOPSIS
Temperature Voltages and Current.
26 [.]XXXXXXXXXXXX[XX][/[ CA | EE | date | disconnect/date | disconnect/udate | endcharge/date | endcharge/udate | IAD | offset | pages/page.[0-7|ALL] | temperature | latesttemp | udate | VAD | VDD | vis |
See the file man3/standard_mini.3so.
]]
Humidity sensor
26 [.]XXXXXXXXXXXX[XX][/[ HIH4000/humidity | HIH5030/humidity | HTM1735/humidity | DATANAB/reset | DATANAB/humidity | humidity | temperature ]]
Barometer
26 [.]XXXXXXXXXXXX[XX][/[ B1-R1-A/pressure | B1-R1-A/gain | B1-R1-A/offset | ]]
Light
26 [.]XXXXXXXXXXXX[XX][/[ S3-R1-A/current | S3-R1-A/illuminance | S3-R1-A/gain ]]
FAMILY CODE
26
SPECIAL PROPERTIES
pages/page.0 ... pages/page.7 pages/page.ALL
read-write, binary
Memory is split into 8 pages of 8 bytes each. Only the pages 3-7 are really
available, and some of that appears to be reserved. See the datasheet for
details.
ALL is an aggregate of the pages. Each page is accessed
sequentially.
temperature
read-only, floating point
Temperature read by the chip at high resolution (~13 bits). Units are
selected from the invoking command line. See owfs(1) or
owhttpd(1) for choices. Default is Celsius. Conversion takes ~20
msec.
latesttemp
read-only, floating point
Latest measured temperature. Reading this node will never trigger a
temperature conversion. Intended for use in conjunction with
/simultaneous/temperature.
VAD VDD
read-only, floating point
Voltage read (~10 bits) at the one of the chip's two supply voltages. Range
VDD= 2.4V to 10V, VAD=1.5 to 10V.
vis
read-only, floating point
Current sensor reading, as a voltage difference. Value is in volts.
Actual current depends on Rsens resistor (see datasheet).
The formula for current is I = vis / Rsens
with units in Amps and Ohms.
Current measurement will be temporarily enabled (see Ienable ) if not
currently enabled (pun intended) for this reading.
CONFIGURATION PROPERTIES
CA
read-write, yes-no
Current Accumulator Configuration flag bit. If "on" (1)
current is stored in page 7 bytes 4-7. If "off" (0) that page can
be used for general storage. See the datasheet for more information.
EE
read-write, yes-no
Current Accumulator Shadow flag bit. If "on" (1) current
reading is stored to EEPROM. If "off" (0) that data will be lost
when chip loses power. See the datasheet for more information
IAD
read-write, yes-no
Current A/D Control flag bit. If "on" (1) current measured at
36.41 Hz. If "off" (0) current measurements won't be made. See the
datasheet for more information.
DATE PROPERTIES
date
read-write, ascii
26 character date representation of the counter value. Increments once
per second.
Setting date to a null string will put the current system time.
Accepted date formats are:
Sat[urday] March 12 12:23:59 2001
Apr[il] 4 9:34:56 2002
3/23/04 23:34:57
current locale setting (your system's format)
disconnect/date
read-write, ascii
26 character date representation of the disconnect/udate value. Time
when the battery pack waws removed from the charger. Format is the same as
the date property.
disconnect/udate
read-write, unsigned integer
Representation of disconnect/date as a number. See udate for
details.
endcharge/date
read-write, ascii
26 character date representation of the endcharge/udate value. Format
is the same as the date property.
endcharge/udate
read-write, unsigned integer
Representation of endcharge/date as a number. See udate for
details.
udate
read-write, unsigned integer
Time represented as a number. udate increments once per second.
Usually set to unix time standard: number of seconds since Jan 1, 1970. The
date field will be the unix representation (ascii text) of
udate and setting either will change the other.
HUMIDITY PROPERTIES
HIH4000/humidity
read-only, floating point
Relative humidity, as percent (1-100 scale).
This value is for a design based on Honeywell's HIH-4000 humidity sensor.
HIH5030/humidity
read-only, floating point
Relative humidity, as percent (1-100 scale).
This value is for a design based on Honeywell's HIH-5030/5031 humidity
sensor.
HTM1735/humidity
read-only, floating point
Relative humidity, as percent (1-100 scale).
This value is for a design based on Humirel's HTM-1735 humidity sensor.
DATANAB/humidity
read-only, floating point
Based on DataNAB's humidity sensor. It uses a HIH-4000 sensor and the current
sensning rather than voltage readings from the DS2438. Calibration values
are stored on chip, and a check field is stored in chip memory.
DATANAB/reset
write-only, yes-no
Used to read calibration values and set the chip to current reading more.
Should be automatically called when a humidity reading is requested.
humidity
read-only, floating point
Relative humidity, as percent (1-100 scale).
The DS2438 actually does not read humidity, but a widely available and
publicised circuit based on the chip, does. This design is for the common
Honeywell HIH-3610 humidity chip. The mostly compatible HIH-4000 chip uses
different temperature compensation, so is better read from the
HIH4000/humidity value. See the datasheets for details.
If the chip is instead a DATANAB design, the DATANAB/humidity value
will be automatically used.
BAROMETER PROPERTIES
B1-R1-A/pressure
read-only, floating point
Pressure reading, as milli-bars, or other unit depending on
settings/units/pressure_scale.
This value is for the B1-R1-A barometer from Hobby-Boards, and assumes the
standard calibration.
B1-R1-A/gain
read/write, floating point
Calibration of pressure gain, as signed number, expressed as the same units as
B1-R1-A/pressure per volt.
This value will be multiplied with the measured voltage to get the
B1-R1-A/pressure reading. It may have to be fine tuned for
calibration purposes, although with the standard sensor, it will often be
good enough to keep it as is.
B1-R1-A/offset
read/write, floating point
Calibration of pressure offset, as signed number, same units as
B1-R1-A/pressure.
This value will be added to the B1-R1-A/pressure reading. The default
value is 904.7 millibars, which may be altered to to compensate for
elevation.
SOLAR SENSOR PROPERTIES
S3-R1-A/current
read-only, floating point
Photo-diode current, in micro-amperes.
This value is for the S3-R1-A solar radiation sensor from Hobby-Boards. Due to
noise and offsets, this value may read as a negative number in low light
conditions. The offset register can be modified to reduce the offset
as much as possible.
S3-R1-A/illumination
read-only, floating point
Illumination, in lux. Always a positive number.
This value is the lux reading from the solar sensor, taking S3-R1-A/gain
into consideration.
S3-R1-A/gain
read/write, floating point
Calibration of photo-diode gain expressed as lux per micro-amperes. The
default value is for the SFH203P photo-diode from Osram, used bare. A
different gain may be used for instance to compensate for an integrathing,
white sphere placed over the diode.
This value is for the S3-R1-A solar radiation sensor from Hobby-Boards, using
the SFH203P photo-diode from Osram.
MULTISENSOR PROPERTIES
MultiSensor/type
read-only, ascii
For iButtonLink's MultiSensor line of 1-wire devices, give the specific
configuration based on a data byte set in memory. (Byte 0 of page 3). This
can help interpretation of the sensor values, distinguishing, current from
water from light.
offset
read-write, integer
Correction for current readings. A value between -256 and 255. See the
datasheet for details. Should be set to the negative of a true zero
current reading.
STANDARD PROPERTIES
See the file man3/standard.3so.
ALARMS
None.
DESCRIPTION
See the file man3/description.3so.
DS2438
The DS2438 (3) is a more complete form of the DS2436 battery chip. Current sensing is available, but not implemented. The major advantage compared to the DS2436 is that two voltages can be read, allowing one to correct circuit measurements for supply voltage and temperature. A better comparison is the DS276x family of chips.
ADDRESSING
See the file man3/addressing.3so.
DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS2438.pdf
http://pdfserv.maxim-ic.com/en/an/humsensor.pdf
http://goo.gl/o9DH0 (Redirects to 009012_2.pdf PDF file on honeywell.com
website)
http://www.phanderson.com/hih-4000.pdf
http://www.humirel.com/product/fichier/HTM1735%20RevG%20.pdf
SEE ALSO
See the file man3/seealso.3so.
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille (paul.alfille@gmail.com) Egil Kvaleberg
| 2003 | OWFS Manpage |